Model Validation for a Waveguide Septum Polarizer


Christian Fazi, William Coburn, Theodore Anthony and Amid Bamba

U.S. Army Research Laboratory

The stepped septum polarizer in square waveguide designed for 1.3 GHz (λ0 = 7.87-inch) was modeled using the Feko (www.feko.info) electromagnetic simulation software. We optimized probe locations and fabricated a pair of antennas for model validation. We describe the Feko model and present measured results for the square waveguide version compared to the model predictions.

25th Annual Review of Progress in Applied Computational Electromagnetics

2009

March



253-258